Liquid Controls SP2200 User Manual
Page 19
17
PRE A
PRE B
PRE A
Followed by last
PRE A entered
PRE B
Followed by last
PRE A entered
PRE A = Preset A (Final Preset);
The set point at which output A
will trigger. If the displayed value
is not the desired preset, press
the key(s) under the digit to be
changed. Press ENTER to load
Preset
PRE B = Preset B (Prewarn);
The set point at which output B
will trigger. If the displayed value
is not the desired preset, press
the key(s) under the digit to be
changed. Press ENT to load
Preset
b tot
or
b rate
tot b
or
tot b
du ##.#
hy ##.#
rate b
or
rate c
hy ##.#
SETTING
THE
PRESETS
Press the PRGM key to choose B TOT (B
relay assigned to total) or B RATE (B relay
assigned to rate). Press enter when the
desired choice is displayed.
This section will only appear if
b tot
is se-
lected. Press the PRG button to choose
tot
b
or
tot c.
Press the ENTER key to enter
the displayed choice
Follow same procedures as A ##.#
This is the hysteresis setpoint
for relay A (00.0 to 99.9). This section will
only appear if
tot c
is selected.
This section will only appear if
b rate
is
selected. Press the PRG. button to choose
rate b
or
rate c.
Press the ENTER key to
enter the displayed choice.
This is the hysteresis setpoint
for relay A (00.0 to 99.9).
ENTER
ENTER
ENTER
ENTER
ENTER
PRESS
ENTER