Liquid Controls SP2850 (MS-649) User Manual
Page 12
Sponsler, Inc.
Model SP2850-TC with MS649
Page 12
DOC#: MN-2850
4-20mA- This sets the compensation input for 4-20mA input when selected and jumper options are installed
correctly (ref. Pg.24)
0-5V- This sets the compensation input for 0-5V input when selected and jumper options are installed correctly (ref.
Pg.24)
0-10V- This sets the compensation input for 0-10V input when selected and jumper options are installed correctly
(ref. Pg.24)
DN TEMP- (DENSITY or TEMPERATURE); Choose to compensate for density or temperature.
DEFLT DN- (DEFAULT DENSITY); The value entered here will be the density value used in the equations when or
if there is a density error (the density input goes above or below range, signal lost or sensor failure).
DENS LOW- (DENSITY LOW); This sets the low value for the density analog input. EX. If 4mA = .2, ENT .2
DENS HI- (DENSITY HIGH); Sets the high value for the density analog input. EX. If 20mA = 20.8, ENT 20.8
DEFLT TP- (DEFAULT TEMPERATURE); The value entered here will be the temperature value used in the
equations when or if there is a temperature error (the temperature input goes above or below range, signal lost or
sensor failure)
TEMP LOW- (TEMPERATURE LOW); This sets the low value for the temperature analog input. EX. If 4mA = 0,
ENT 0
TEMP HI- (TEMPERATURE HIGH); This sets the high value for the temperature analog input. EX. If 20mA = 100.0,
ENT 100.0
MANUAL- This allows the user to enter in the operating temperature or density when the compensation input is not
used.
ENT DEN- (ENTER DENSITY); When the compensation input is set for manual and density, this prompt allows the
user to enter the density of the liquid at operating conditions.
ENT TEMP- (ENTER TEMPERATURE); When the compensation input is set for manual and temperature, this
prompt allows the user to enter the temperature of the liquid at operating conditions.
FLUID- This section of the programming menu is used to set up the fluid properties.
REF DENS- (REFERENCE DENSITY); Allows the user to enter the reference density of the liquid.
REF TEMP- (REFERENCE TEMPERATURE); Allows the user to enter the reference temperature of the liquid.
EXP COEF- (EXPANSION COEFFICIENT); This allows the user to enter the thermal coefficient of expansion for
the liquid. The value must be entered in straight decimal notation. EX. If the coefficient of expansion is 115 X 10
-6
,
then enter 0.000115.
FLOW EQ- (FLOW EQUATIONS); This section of the programming menu is used to set up the type of flow
equation used.
MASS- When this is selected the flow equation will be calculated for mass (weight i.e. pounds, Kgrams, etc.)
COR VOL- (CORRECTED VOLUME); When this is selected the flow equation will be calculated for corrected
volume (area i.e. gallons, liters, etc.)