Product Configuration
MAP FRoM PRoDUCT To LCR
CALIbRATIon
If the
Map from Product to LCR Calibration box is
checked in the Source and Destination window, you must
assign products’ LCR-II calibrations differently.
LCLoad still creates a list of products and assigns codes
and generic descriptions, but aligning the products to the
correct LCR-II calibration is done in the Product.500 not
FuelType.500. In fact, the FuelType.500 window will be
eliminated from the button list.
Product.500 Window
The
Fuel Type Code field will be replaced with a LCR
- Calibration field. LCR specifies which LCR-II to read,
and
Calibration specifies the correct calibration (each
LCR-II can contain four calibrations) to use.
Product Record
The Product Record window has a
Map Product to
LCR Calibration section to enter the correct meter and
calibration values.
To correctly align your product with the proper LCR-
II calibration, you must enter the correct meter,
LCR
network node (use 1 for single meter systems), and the
correct calibration setting,
LCR-II Calibration number.
A LCR-II calibration ticket should print this information.