Product configuration, Map from product to lcr calibration – Liquid Controls DMS Office User Manual

Page 26

background image

26

Product Configuration

MAP FRoM PRoDUCT To LCR

CALIbRATIon

If the

Map from Product to LCR Calibration box is

checked in the Source and Destination window, you must

assign products’ LCR-II calibrations differently.
LCLoad still creates a list of products and assigns codes

and generic descriptions, but aligning the products to the

correct LCR-II calibration is done in the Product.500 not

FuelType.500. In fact, the FuelType.500 window will be

eliminated from the button list.

Product.500 Window

The

Fuel Type Code field will be replaced with a LCR

- Calibration field. LCR specifies which LCR-II to read,

and

Calibration specifies the correct calibration (each

LCR-II can contain four calibrations) to use.

Product Record

The Product Record window has a

Map Product to

LCR Calibration section to enter the correct meter and

calibration values.
To correctly align your product with the proper LCR-

II calibration, you must enter the correct meter,

LCR

network node (use 1 for single meter systems), and the

correct calibration setting,

LCR-II Calibration number.

A LCR-II calibration ticket should print this information.