beautypg.com

4 programming users – Controlled Products Systems Group 212ILW User Manual

Page 20

background image

212iLW/242iLW Standalone Keypad
Installation/Programming Manual

Document # 6050700, Rev. 1.1, D2d

20


Command/Action

Keys to Enter/Details

Command 32.
Change Keypad
Parameters

32 # parameter # value # * *

Parameter Value
0 – Duress Output Duration

1 – 255 (default = 5)

1 – Panic Output Duration

1 – 255 (default = 5)

2 – Error Lockout Threshold

1 – 50 (default = 3)

3 – Error Lockout Duration

1 – 255 (default = 10



7.4 Programming Users


Command/Action

Keys to Enter/Details

Master Code

User #1 is the master code; it can access all
commands in program mode. The default code is
1234. The master code can be programmed
with command 50 or command 60 as a
standard user only.

Supervisor Code

User #2, when programmed, is the supervisor
code. The supervisor can access program mode,
but is limited to adding and deleting users, as
well as enabling or disabling users. The
supervisor code can’t change, delete, or disable
the master code or supervisor code itself.

Add Standard User
(short version)

user location # code * code *

Add User with
Specific Unlock Time

unlock time # user location # code * code *
(This command is used to program a user with a
specific unlock. This user activates the virtual
lock output.)

Delete User

user location # * *