Controlled Products Systems Group 1815-051 User Manual
Weigand keypad installation and programming
Weigand Keypad Installation and Programming
These instructions apply to the following DoorKing Digital Keypads: 1815-050, 1815-051, 1815-052,
1838-120, 1504-120. When used to control entry through an automated vehicular gate system, the
keypad must be mounted a minimum of 10-feet away from the gate and gate operator, or mounted
in such a way that the person using the keypad cannot come into contact with the gate or gate
operator.
These keypads output their data in a 26-bit weigand format and must be connected to an access
controller such as the DKS models 1833, 1835, 1837 or 1838.
WIRING
Use Belden 9418 or 9931 for wiring.
TERM 1
Input power 12-24 volt AC or DC NEGATIVE / WEIGAND COMMON (BLACK)
TERM 2
Input power 12-24 volt AC or DC POSITIVE (RED)
TERM 3
Earth Ground
TERM 4
Weigand COMMON
TERM 5
Not Used
TERM 6
Weigand DATA 0 (GREEN)
TERM 7
Weigand DATA 1 (WHITE)
TERM 8
Not Used
1
2
3
4
5
6
7
8
Wh
ite
Gr
ee
n
Re
d
Bl
a
c
k
White - DATA 1
Green - DATA 0
Red - POWER
Black - COMMON
Belden 9418
To Access
Controller
Master Code
LED
Lights
Gray
Orange
12-24 Volt
AC or DC
1815-064-F-8-12