Control board overview, Additional features, Bipart delay switch – Controlled Products Systems Group LA500 User Manual
Page 32: Learn button, Timer-to-close dial, Reversal force dial, Test buttons, Status leds

30
SET OPEN
SET CLOSE
MOVE
GATE
OFF
5
10
60
180 MIN
MAX
(SECONDS)
OFF
ON
OPEN
CLOSE
ST
OP
INPUT POWER
BATT CHARGING
TIMER
GATE MOVING
BATT LOW
ACC PWR OVLD
DIAGNOSTIC
CODES
STATUS:
SBC
“FIRE
DEPT ”
OPEN
EXIT
SHADOW
CLOSE
EYES/
INTERRUPT
LOCK
N.O.
COM
N.C.
+ -
+ -
ACCESSOR
Y
POWER
ON SW
.
EXP
.
BOARD
XMITTER
NETWORK
PRESS &
RELEASE
TO BEGIN
SETUP
CLASS 2 SUPPLY
24 VOLTS
1
LIMIT
2
- +
+ -
J5
+
SOLAR /
CHARGER
J15
+
BATT
+
DC
POWER
ID RESET
ALARM
GROUND
BR GRN WT YE BLU RED
BR GRN WT YE BLU RED
SBC
Com
Com
Com
Com
Com
Fire Dept
Exit
Shadow
Interrupt
Comm Link Data A
Comm Link Data B
Close (+)
Close (-)
Lock N.C. (Maglock)
Com
Lock N.O. (Solenoid)
Com (-)
AccPower +24 Vdc
Com (-)
AccPower +24 Vdc
Single Button
Control Station
Fire Dept.
Exit Loop
Shadow Loop
Interrupt Loop
Comm Link
Open Direction
Safety
Close Direction
Safety
Mag and
Solenoid Lock
A
B
C
D
E
F
G
H
I
J
K
L
CONTROL BOARD OVERVIEW
ADDITIONAL FEATURES
CONTROL BOARD OVERVIEW
SET OPEN Button
The SET OPEN button sets the OPEN limit. See Adjust Limits section.
SET CLOSE Button
The SET CLOSE button sets the CLOSE limit. See Adjust Limits section.
MOVE GATE Button
The MOVE GATE buttons will either open or close the gate when the operator is in Limit setting mode. See Adjust Limits section.
BIPART DELAY Switch
The Bipart delay switch is used only for dual gates. See Bipart Delay section.
LEARN Button
The LEARN button is for programming remote controls and the network.
TIMER-TO-CLOSE dial
The TIMER-TO-CLOSE (TTC) dial can be set to automatically close the gate after a specified time period. The TTC is factory set to OFF. If the
TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a control. Rotate the
TIMER-TO-CLOSE dial to the desired setting. The range is 0 to 180 seconds, 0 seconds is OFF.
NOTE: Any radio command, single button control, or CLOSE command on the control board prior to the TTC expiring will close the gate.
The TTC is reset by any signals from the open controls, loops, close edges, and close photoelectric sensors (IR’s).
REVERSAL FORCE dial
The REVERSAL FORCE dial adjusts the force. See Force Adjustment section.
TEST BUTTONS
The TEST BUTTONS will operate the gate (OPEN, STOP and CLOSE).
STATUS LEDs
The STATUS LEDs are diagnostic codes for the operator. See Status LED Chart in the Troubleshooting section.
Switched ON with gate motion. Always ON with
expansion board connected. Switches Off to save
battery power if expansion board disconnected.
Always ON
Acc. Power
Open (+)
Open (-)