DIP Switch Setup
Camera ID Setup
Switch State
Protocol
P0
(Pin 1)
P1
(Pin 2)
P2
(Pin 3)
OFF
OFF
OFF
PELCO-D, 2400 bps
ON
OFF
OFF
PELCO-D, 9600 bps
OFF
ON
OFF
PELCO-P, 4800 bps
ON
ON
OFF
PELCO-P, 9600 bps
OFF
OFF
ON
SAMS.. , 4800 bps
ON
OFF
ON
PANA.. , 9600 bps
◎ Select the appropriate Protocol with DIP switch combination.
Communication Protocol Setup
◎ If you want to control using DVR or P/T controller, their protocol must be identical to
camera. Otherwise, you can not control the camera.
◎ If you changed camera protocol by changing DIP S/W, the change will be effective
after you reboot the camera.
◎ Factory default of protocol is “Pelco-D, 2400 bps”.
◎ If you want to information using protocol setup, download is possible form CNB home
page.
- DOWNLOAD
http://www.cnbtec.com/en/html/down/data_down.php
Pin
1
2
3
4
5
6
7
8
ID Value
1
2
4
8
16
32
64
128
ex) ID=5
on
off
on
off
off
off
off
off
ex) ID=10
off
on
off
on
off
off
off
off
◎ ID number of camera is set using dip switch. The example
is shown bellow.
◎ The range of ID is 1~255. Do not use 0 as camera ID. Factory default of
Camera ID is 1.
◎ If you want to control a certain camera, you must match the camera ID with Cam
ID setting of DVR or Controller.
ON
OFF
ON
PANA.. , 9600 bps
OFF
ON
ON
Bosch , 9600 bps
ON
ON
ON
SAMS.TW, 9600 bps
10
11