beautypg.com

CNB SFM-21VF User Manual

Page 7

background image

DIP Switch Setup

Camera ID Setup

Switch State

Protocol

P0

(Pin 1)

P1

(Pin 2)

P2

(Pin 3)

OFF

OFF

OFF

PELCO-D, 2400 bps

ON

OFF

OFF

PELCO-D, 9600 bps

OFF

ON

OFF

PELCO-P, 4800 bps

ON

ON

OFF

PELCO-P, 9600 bps

OFF

OFF

ON

SAMS.. , 4800 bps

ON

OFF

ON

PANA.. , 9600 bps

◎ Select the appropriate Protocol with DIP switch combination.

Communication Protocol Setup

◎ If you want to control using DVR or P/T controller, their protocol must be identical to

camera. Otherwise, you can not control the camera.

◎ If you changed camera protocol by changing DIP S/W, the change will be effective

after you reboot the camera.

◎ Factory default of protocol is “Pelco-D, 2400 bps”.
◎ If you want to information using protocol setup, download is possible form CNB home

page.

- DOWNLOAD

http://www.cnbtec.com/en/html/down/data_down.php

Pin

1

2

3

4

5

6

7

8

ID Value

1

2

4

8

16

32

64

128

ex) ID=5

on

off

on

off

off

off

off

off

ex) ID=10

off

on

off

on

off

off

off

off

◎ ID number of camera is set using dip switch. The example

is shown bellow.

◎ The range of ID is 1~255. Do not use 0 as camera ID. Factory default of

Camera ID is 1.

◎ If you want to control a certain camera, you must match the camera ID with Cam

ID setting of DVR or Controller.

ON

OFF

ON

PANA.. , 9600 bps

OFF

ON

ON

Bosch , 9600 bps

ON

ON

ON

SAMS.TW, 9600 bps

10

11

This manual is related to the following products: