Technical data – Burkert Type 6608 User Manual
Page 4

12
7. Technical daTa
Operating conditions
7.1.
Warning!
Risk of injury
Malfunction if used outside!
Do not use Type 6128 and Type 6608 outdoors and avoid
•
heat sources which may cause the allowable temperature
range to be exceeded.
Allowable temperatures
Ambient temperature
0 - +60 °C
Medium temperature
0 - +70 °C
Media
neutral and aggressive, gaseous and
liquid media which do not attack body
and seal materials
see Buerkert Chemical Resistance Chart
(
www.burkert.com
)
Protection class IP40
english
13
conformity
7.2.
CE mark conforms to EMC Directive 2004/108/EC
(only if cables, plugs and sockets connected correctly).
mechanical data
7.3.
Dimensions
See data sheet
Body material
Type 6128:
PPS,
Type 6608:
PEEK
Seal material
Type 6128:
FKM, EPDM
Type 6608:
FFKM
FKM and EPDM on
request
english
13
14
7.4. pneumatic data
Circuit functions (CF)
A
A
P/NC
2/2-way valve, direct-acting,
normally closed
B
B
P/NO
2/2-way valve, direct-acting,
normally open
C
A in/out
P/NC R/NO
3/2-way valve, direct-acting,
normal output A unloaded
D
B in/out
P/NO R/NC
3/2-way valve, direct-acting,
normal output B pressurized
T
A in/out
P/NC R/NO
3/2-way valve, direct-acting,
universal function
english
15
Note the information specified on the label for
voltage, type of current, and pressure.
Pressure range
Vac - 10 bar
Port connections
Threaded connection G1/8 or
NPT1/8
Flange connection
english
15
Type 6128, 6608