Maintenance, Cleaning

Type 2036

9

MainTenance, cleaninG

9.1 servicing intervals

Check the diaphragm valves regularly for proper operation in terms of
assembly, installation and operation.

9.2 servicing work

Do not repair the device yourself, but replace it with an
equivalent device. Repairs may be performed by the manu-
facturer only.

9.2.1 actuator

The actuator of the diaphragm valve is maintenance-free provided it
is used according to these operating instructions.

9.2.2 Wearing parts of the diaphragm valve

The diaphragm is subject to wear.

If leakage occurs replace the diaphragm.

A bulging diaphragm may reduce the flow rate.

The replacement of the wearing parts is described in the
operating instruction in chapter "Repairs".

9.3 cleaning

note!

avoid causing damage with cleaning agents.

▶ Before cleaning, check that the cleaning agents are compatible

with the device materials.

Observe instructions in chapter "3.1 Use in Ex area"

.

10 sPare ParTs

Caution!

risk of injury and/or damage by the use of incorrect parts.
Incorrect accessories and unsuitable spare parts may cause injuries
and damage the device and the surrounding area.

▶ Use original accessories and original spare parts from Bürkert

only.

The diaphragm is available as a spare part for the diaphragm valve
Type 2036.

If you have any queries, please contact your Bürkert sales
office.

english