beautypg.com

eLine Technology iVMS-2000 V2.0.2 User Manual

Page 76

background image

iVMS-2000 User Manual


71

The General Settings mainly includes system parameters such as Log Keeping days,

Snapshot Path, etc.

Parameters

Description

Image Format

Select JPG or BMP as the file format for live preview/playback
snapshot images

Snapshot Path

Click […] and select default file path to save the snapshot

images

Log Keeping Days

Log files can be keep in the database for a maximum of 7

days, 15 days, 30 days (default), 60 days, 90 days or 120
days, and the previous log files will be automatically deleted

when it expires the log keeping days.

Switch Time

Set the auto switch time interval for live preview cameras as
3 seconds, 5 seconds (default), 10 seconds, 15 seconds, 30

seconds or 1 minute

Buzzer

If [Buzzer] is enabled, then the buzzer on the PC

motherboard will sound when there is exception alarm
(illegal network access, hard disk full or hard disk read/write
error). This option is disabled by default

Auto Lock

If [Auto Lock] is enabled, then the iVMS-2000 software will
be locked automatically after there is no keyboard/mouse

operation for over a certain time period, and users will need
to login again to operate the software. Auto Lock option can

be set to “disable” (default), or lock after 1 minutes, 5
minutes, 10 minutes, 30 minutes or 1 hour

Auto Reboot

PC and iVMS-2000 software will reboot on the preset [Auto

Reboot] time. Click the checkbox to enable/disable this
option. If [Auto Reboot] is enabled, users also need to

configure Windows User/Password and also Reboot Time to
let the configuration take effect

Windows User

User name to login the Windows OS

Windows Password Password for the Windows login user
Reboot Time

Set the reboot date and time each week

Note: Users need to click [Save] button after parameter modification to save the