beautypg.com

11 zero offset, 12 programmed resolution, 13 programmed total resolution – BEI Sensors MHK5 Absolute Hollow Shaft Encoder User Manual

Page 29: 14 serial number

background image

Revision 03/10

BEI Sensors Profibus Manual serie M

Page 29

6.2.11 Zero offset

The zero offset is output in diagnostic bytes 32 to
35.

6.2.12 Programmed resolution

The programmed resolution per revolution is output
in diagnostic bytes 40 to 43. The value is only valid
if the scaling factor is based on the parameter
„resolution per revolution“ (cp. 5.1.3).

6.2.13 Programmed total resolution

The programmed, respectively calculated total
resolution is output in diagnostic bytes 44-47.

6.2.14 Serial number

Diagnostic bytes 48-57 are intended for a serial
number.
With the current version the serial number is not
saved in the encoder, the bytes contain the default
value 2A hex.