7 - 12

Balancer mode

: direct printing of a balancing certificate by using the portable printer
provided (optional). The certificate gives the unbalances on the
correction planes (in units U), as well as the values of vibration (overall
and synchronous) of these planes. The following is an example of this
certificate:

: function involving splitting of the correction weight on two presettable

angles (see 7-13 Splitting of correction weight. )

: : shows the program archive (to allow saving or eliminating a program)

As in calibration, to start or stop measurement, press

; while the

measurement is active a pop-up appears to indicate the quality of measurement of each
channel.
After making the corrections indicated, the measurement-correction procedure can be
repeated until the required conditions are met (typically vibration measured by the
sensors lower than a certain value).