beautypg.com

CEMB USA C88 (B) User Manual

Page 38

background image

I 0709 - 38

GB

Err.59

Radial and lateral Sonar readout error.
Lateral and radial Sonar values are insuffi -
cient for correct measurement of radial and
lateral eccentricity.

1.

Check points Err. 55

2.

Check points Err. 57

Err.65

Printer timeout

1. Check that a printer is present.
2. Check the code of the processor card.
3. Check the printer <-> processor card connection.
4. Run the printer test function.

Err.66

Printer buffer error

1.

Reset the printer.

2.

Repeat the print function.

Err. 70

Error - lift down: the lift does not go up after
pressing the button indicated in Fig. 1.

1. Check proper functioning of the lift position microswitch
2. If the spindle is closed, check that the mounted wheel has been

lifted with the lift. if not, manually dismount the wheel and follow
the instructions from step 1

Err. 71

Error - lift up: the lift does not go down
after locking the wheel or after pressing the
button indicated in Fig. 3.

1. Check proper functioning of the lift position microswitch