CEMB USA C88 (B) User Manual
Page 18
I 0709 - 18
6
FI
FE
GB
4.7.1 - WHEEL LOCKING
►
The wheel is automatically locked when reaching the correct angular position for weight application on the inside and
outside, turning it slowly by hand. To unlock the wheel, turn it hard to move it from the correct correction position.
If the unbalance is within tolerance, the wheel is not automatically locked.
4.
►
7.2 - EXACT POSITIONING OF THE ADHESIVE WEIGHT BY MEANS OF THE GAUGE WITH CLIPS
Option enabled (
AUTOMATIC POSITION REPEATER
)
:
pull out the gauge to automatically access the function
▪
If the option is disabled, the position repeater screen can be accessed in 2 different ways:
Pull out the gauge after placing the wheel in the correction position on one of the two sides
▪
Press the button
▪
at any time
Always pull out the gauge to position A as shown in Figure 4
A mobile coloured arrow [
▪
] indicates the approach of the weight towards the correction position.
W
▪
hen a fi xed arrow [
] is reached, rotate the wheel to correction position (FI or FE) and apply the
counterweight by rotating the gauge tip towards the outside, into the position where the pincer touches the wheel
(
where appropriate use the weight pusher
).
The correction weight application position is automatically reset in relation to the position of the distance +
▪
diameter gauge (pos. A, fi g. 4).
When the acoustic signal is enabled (
▪
ACOUSTIC SIGNAL
), attainment of the fi xed arrow
status
[
] is accompanied by a “beep”.
If gauge locking is enabled (
▪
GAUGE LOCKING
), when a fi xed arrow [
] is reached,
the gauge is automatically locked to prevent shifts during application of the correction weight.
To release and bring the gauge back to the rest position, lower it to below 10” diameter.