5.3 - GENERAL SETUP
►
(
MENU ACCESS DIAGRAM)
The Setup screen provides the user with many possibilities required for presetting the machine in relation to his own
requirements. Such settings remain unaltered even when the machine is switched off.
The following buttons are enabled:
: return to previous window
:
return to measurement screen
: for parameter selection.
5.3
►
.1 - LANGUAGE
This function allows selection of the language to be used for displaying descriptive and diagnostic messages regar-
ding machine operation.
5.3.2 - SCREEN-SAVER
►
If enabled (ON), if the machine is left unused on the initial frame, the screen saver automatically comes on. The
function can be disabled by setting “OFF”.
5.3.3 - ACOUSTIC SIGNAL
►
When “ON” is selected, the acoustic signal (beep) is enabled in the following cases:
when any push button is pressed;
▪
when dimensions are acquired in automatic mode;
▪
when the correct angular position for weight application is reached in the Measurement screen;
▪
when the correct angular position for weight application is reached in the Position Repeater screen.
▪
5.3.4 - SETTING THE CLOCK
►
Used to set date and time correctly. Follow the instructions on the screen.
5.3.5 -
►
GUARD OPENING DURING SPIN
Selecting “ON” the option to open the guard (when the motor is off) during the spin is enabled. If the guard is opened
when the motor is on, error 5 (guard open) is displayed.
Selecting “OFF”, error 5 (guard open) will always be signalled when the guard is opened.
5.3.6 - AUTOMATIC POSITION REPEATER
►
Enables and disables the automatic position repeater control (
INDICA
TION OF EXACT CORRECTION WEIGHT
POSITION
)
5.3.7 - OPTIONS
►
5.3.7.1 -
►
LIFT ZERO WEIGHT
Enables/disables automatic lift control
5.3.7.2 - ECCENTRICITY SETUP
►
Enables display of a menu where the following parameters can be set:
Side eccentricity measurement
enable
Enables/disenables lateral eccentricity measurement.
Radial eccentricity measurement
enable
Enables/disenables radial eccentricity measurement.
Eccentricity unit of measure
It is possible to select display of eccentricity measurements in mm or
inches.
First harmonic limit
The fi rst harmonic limit beyond which it is felt suitable to rotate the tyre
on the 180° rim. Recommended Limit = 1.2 mm.
Rim fi rst harmonic limit
Represents the fi rst harmonic limit of the rim below which it is not
considered appropriate to turn the tyre on the rim. Recommended limit:
0.3 mm.
Minimum correction limit
Represents the minimum correction limit obtainable below which it is
not considered appropriate to turn
the tyre on the rim. Recommended
limit: 0.8 mm.