I 0709 - 32

GB

5.4.5

- STATIC ALWAYS ENABLED

Simultaneous display of the selected correction plane unbalance as well as STATIC unbalance can be enabled/disa

bled. The static frame can always be selected by pressing the

button from the measuring frame.

5.5 - CORRECTION METHOD

One of the three possible correction methods can be selected based on the specifi c requirements of the customer.

5.5.1

- STANDARD CORRECTION METHOD

The wheel balancer considers the unbalance within tolerance when the value of each single plane is lower than the
tolerance set.

5.5.2 - EXTERNAL PLANE CORRECTION METHOD

If correcting with adhesive weights, the unbalance is considered within tolerance when the recalculated external
plane weight (clip-on weights) is lower than the tolerance set.
Additional windows appear on the screen always displaying the residual external plane value (clip-on weight):