5.3.7.7

- GAUGE LOCKING ENABLE

Enables/disables distance gauge locking when the correct distance has been reached to apply the adhesive weight to
correct the unbalance.
To release the gauge, lower it to below 10” diameter.

5.4 - BALANCING SETUP

5.4

.1 - UNIT OF UNBALANCE MEASUREMENT

It is possible to select whether to display the unbalance values expressed in grams or ounces.

5.4.2 - UNBALANCE DISPLAY PITCH

This represents the unbalance display pitch and varies in relation to the unit of measurement selected. The selection
“5 g” (1/4 oz) enables display of the correction values on both sides such as to bring the static unbalance to 0 (theore-
tical). It is recommended to preset this function as standard on the machine as it improves the balancing
quality. The computer makes a complex calculation which allows cancelling the residual static unbalance by
varying the value and position of the counterweights fi xed in steps of 5 grams (1/4 oz).

5.4

.3

- TOLERANCE (

CORRECTION METHOD

)

This is the unbalance threshold below which the word “OK” instead of the unbalance value appears on the screen at
the end of the spin:

The tolerance varies based on the correction method selected.
In the case of IC (Intelligent Correction), set the static tolerance limit and the average weight of a reference wheel of
6” in width and 15” in diameter.

The following buttons are enabled:

parameter

selection

during

setting

parameter

decrease/increase

during

setting

default parameter setting recommended by the manufacturer

return to the measurement screen

return

to

previous

frame.

5.4.

4 - RUN WITH GUARD CLOSED

When “ON” is selected, automatic run start is enabled when the guard is closed.