Fe fi – CEMB USA C88 (B) User Manual
Page 15
![background image](/manuals/326189/15/background.png)
I 0709 - 15
FE
FI
GB
The other enabled buttons are:
USER CONTROL
This
button
is used to improve the dimensional calibration of large-diameter
wheels
such as off-road, trucks, wheels which protrude signifi cantly from the rim.
Press this button several times to select the type of tyre projection (from 1.0” to
2.0”).
The option is disengaged at the end of current Width Measurement.
select the type of weight to apply (
CORRECTION METHODS
).
return to initial frame
launch
balancing.
4.5.2 - AUTOMATIC WIDTH MEASUREMENT
►
Slowly lower the guard after making the automatic measurement of the distance + diameter to automatically measure
the wheel width.
If the width measured is incorrect (out of range), the following message appears:
“Sonar measure is out of range:”
“F1 = repeat”
“F2 = manual set-up”
Press F1 to re-lower the guard and repeat the width measurement. Press F2 to go to the dimensions panel for
manual insertion of the width measurement. Manually presetting is possible by using the push buttons as described in
"
DIMENSIONS".
4.5.3
►
- ALUS WHEEL AUTOMATIC PRESETTING (Adhesive weights)
Make two consecutive measurements inside the rim on two correction planes of your choice as indicated in fi gure 5.
When the acoustic signal is enabled (
ACOUSTIC SIGNAL
), the acquisition is accompanied by a “beep”.
The enabled buttons are:
USER CONTROL
selection of clip or adhesive weight for inside.
selecting the manual dimension presetting screen
return to initial screen.
balancing
run.
Position of adhesive
weight