MONitor[:STATe]

DISPlay:MONitor[:STATe] <mode>

turns the monitor mode on or off.

Parameters

Parameter Name

Parameter Type

Range of Values

<mode>

boolean

ON l OFF | 1 | 0

Comments

Monitoring Switchbox Channels: DISPlay:MONitor[:STATe] ON
or DISPlay:MONitor[:STATe] 1 turns the monitor mode ON to show
the channel state of the selected module. DISPlay:MONitor[:STATe]
OFF or DISPlay:MONitor[:STATe] 0 turns the monitor mode OFF.

Selecting the Module to be Monitored: Use the
DISPlay:MONitor:CARD <number> |AUTO command to select the
module.

Monitor Mode on an Agilent E1301B Mainframe Display: A
typical display for the Agilent E1364A Form C Switch module
follows, where all channels (all relays) are closed.

0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15

*RST Condition:

DISPlay:MONitor[:STATe] OFF | 0

Example

Enabling the Monitor Mode:

DISP:MON:CARD 2

Selects module #2 in a switchbox

DISP:MON 1

Turns monitor mode ON