2.3 Technical Data
2.3.1 Technical Data 230V Class
1) The wire gauge is based on the maximum fuse rating, copper wire with minimum 75°C insulation rating, THHW or equivalent. If
branch circuit protection is selected based on rated input current, the wire size could be reduced.
2)
This data is only valid for units with internal brake transistor GTR 7 (see "unit identification")
3)
With units with integrated EMI filter the distance is less:
up to max. 5m line length and 4kHz operating frequency = Limit Value B (EN 55011)
up to max. 10m line length and 16kHz operating frequency = Limit Value A (EN 55022)
4) Rated operation means rated input voltage, rated output current, and rated carrier frequency.
Inverter Size
5
7
9
10
12
Recommended Motor Power
[hp]
1/2
1
2
3
5
Housing size
A
A
B
B
D
Input Ratings
Supply voltage
[V]
180...260 ±0 (230 V rated voltage)
Supply voltage frequency
[Hz]
50 / 60 +/- 2
Input phases
1
1
1
3
1
3
3
Rated input current
[A]
4.0
8.0
14 9.5 19 13
21
Recommended maximum input fuse
[A]
15
15
20 15 25 20
25
Recommended wire gauge
1)
[awg]
14
14
12 14 10 12
10
Output Ratings
Rated output power [kVA]
0.9
1.6
2.8
4.0
6.6
Rated motor power [kW]
0.37
0.75
1.5
2.2
4.0
Rated output current
[A]
2.0
4.0
6.8
9.6
15.2
Peak current (30 seconds)
[A]
4.1
7.2
12.6
18.0
29.7
Over current fault (E.OC) trip level
[A]
5.0
8.6
15.1
21.6
35.6
Overload curve (see annex)
1
Output voltage
[V]
3 x 0...V input (3 x 0...255V)
Output frequency
[Hz]
Generally 0 to 1600Hz (limited by control
board and carrier frequency)
Rated switching frequency [kHz]
4
8
16
8
8
Maximum switching frequency [kHz]
8
8
16
16
16
Power loss at rated operation
4)
[W]
30
55
90
105
210
Stall current at 4kHz
[A]
2.3
4
7
10
16.5
Stall current at 8kHz
[A]
2.3
4
7
10
16.5
Stall current at 16kHz
[A]
–
–
7
8
10
Braking Circuit
Min. braking resistance
2)
[Ohm]
-
-
47
33
27
Typ. braking resistance
2)
[Ohm]
-
-
68
56
33
Max. braking current
[A]
-
-
9.5
12
15
Installation Information
30
30
330
30
30
330
–
–
Tightening torque for terminal strip [in lb]
4.5
Environmental
Max. heat sink temperature TOH
[°C]
90°C / 194°F
Storage temperature
[°C]
-25...70 °C / -13…158°F
Operating temperature
[°C]
-10...45 °C / 14…113°F
Housing design / protection
Chassis / IP20
Relative humidity
max. 95% without condensation
Approvals
Tested in accordance with…
EN 61800-3 /UL508C
Standards for emitted interference
EN 55011 Class B / EN 55022 Class A
Standards for noise immunity
IEC 1000-4-2 / -3 / -4 / -5/ -6
Climatic category
3K3 in accordance with EN 50178
330
Max. shielded motor cable length at 8 kHz
3)
[ft]
Max. shielded motor cable length at 16kHz
3)
[ft]
Max. shielded motor cable length at 4 kHz
3)
[ft]
130