Operation of the Drive
As an accessory for displaying and editing "CP" parameter values,
a "digital operator" is necessary. To remotely mount the digital
operator, a operator remote cable is required. To prevent malfunc-
tions, the inverter must be brought into
nOP
status
(remove signal
from control release terminal 16)
before connecting / disconnect-
ing the operator. When starting the inverter without an operator,
it is started with the last stored values.
4. Operation of
the inverter
4.1 Digital Operator
Only use the operator interface for the serial data transfer
to RS232, 485. The direct connection from PC to the inverter
is only valid with a special cable otherwise it will lead to
the destruction of the PC-interface!
Standard Operator: Part No. 92C84982310000
Serial Operator: Part No. 92C84982320000
5
4
3
2
1
9
8
7
6
ANTRIEBSTECHNIK
START
STOP
FUNC.
SPEED
ENTER
F/R
Double function keypad
Operating-Error display
Normal "LED on"
Error "LED blinks"
5-digit LED Display
Serial Communication
Transmit "LED on"
(Ref.: 92C84982320000)
RS232, RS485
(Ref.: 92C84982320000)
PIN RS485
Signal
Meaning
1
–
–
reserved
2
–
TxD
Transmitter signal, RS232
3
–
RxD
Receiver signal, RS232
4
A'
RxD-A
Receiver signal A, RS485
5
B'
RxD-B
Receiver signal B, RS485
6
–
VP
Voltage supply-Plus +5V
(I
max
= 10 mA)
7
C, C'
DGND
Data reference potential
8
A
TxD-A
Transmitter signal A, RS485
9
B
TxD-B
Transmitter signal B, RS485