Adjustment of the Drive

The positioning function enables the approach of a position with a signal
from different frequencies. With parameter CP.27 the stop position can
be adjusted, which entails an additional constant running time. CP. 27
selects positioning on/off and if positioning is on and additional run time.
This additional run time is added to every speed. In the example below
CP.27 is set to 0.00. This selects posiitioning without a positioning delay.

Positioning Delay

Factory setting CP.22:

27

Note:

Enter-Parameter

Relay output 2

Switching level

This parameter determines the switching point for relay output 2. Since the
operator display can only view 5 characters, the last digits are not
displayed for the higher values. Note; all conditions chosen with CP.22
don't require use of CP.23.

Adjustment range: -30000.00...30000.00
Resolution:

0.01

Factory setting:

0.00

Start

(pin 14)

Stop

(pin 11)

Stop From

Max Speed

Speed 1

(MAX)

Speed 2

Stop From

Low Speed -

No Positioning

Speed 1

(MAX)

Speed 2

Stop From

Low Speed -

Positioning

Speed 1

(MAX)

Speed 2

0 Hz

0 Hz

0 Hz

Additional run
time so that the
stop point is the
same as the
stop from the
max speed.