Error diagnosis – DE-STA-CO F5-B AC Inverter Drive User Manual
Page 49
49
Error Diagnosis
E.PUCO E. power unit common.
22
Error: Parameter value could not be written to the power
circuit. Acknowledgment from PC <> OK
E.OH2 ERROR motor protection
30
Error: Electronic motor protective relay has tripped.
E. EF
ERROR external fault
31
Error: External error is triggered when a digital input is being
programmed as an external error input.
E.ENC ERROR encoder
32
Error: Encoder cable and/or connection wiring
E.nOH no E. over heat pow. mod.
36
Internal or external temperature has dropped to a safe level.
E.SET ERROR set
39
Error: Set selection: It has been attempted to select a locked
parameter set.
E.PRF ERROR prot. rot. for.
46
Error: Locked direction of rotation clockwise
E.PRR ERROR prot. rot. rev.
47
Error: Locked direction of rotation counterclockwise
E.PUCI E. power unit code inv.
49
Error: during the initialization the power circuit could not be
recognized or was identified as invalid.
E.PUCH E. power unit changed
50
Error: Power circuit identification was changed; with a valid
power circuit this error can be reset by writing to SY.3 (applica-
tion mode).
E.DRI
ERROR driver relay
51
Error: Driver relay. Relay for driver voltage on power circuit has
not picked up although control release was given.
E.HYB ERROR hybrid
52
Error: Invalid encoder interface identifier
E.CO1 ERROR counter overrun 1
54
Error: Counter overflow encoder channel 1
E.CO2 ERROR counter overrun 2
55
Error: Counter overflow encoder channel 2
E. BR
ERROR brake
56
Error: This error can occur in the case of switched on brake
control, if the load is below the minimum load level Pn.58
(application mode) at start up.
E.INI
ERROR initialization MFC
57
Error: MFC not booted
E.HYBc ERROR hybrid changed
59
Error: Encoder interface identifier has changed, it must be
confirmed over ec.0 or ec.10 (application mode).
E.ccd
ERROR calculation drive
60
Error: during the automatic motor stator resistance measurement
E.OS
ERROR over speed
105
Error: Real frequency is bigger than the max. Output frequency
A.OHI
ABN.STOP overheat int.
87
Warning: overtemperature in the interior
A.nOH no A. overheat pow.mod.
88
Warning: no more overtemperature of power module
A. OH
A.STOP overheat pow.mod 89
Warning: Overtemperature of power module