Installation and connection, Examples of correct and incorrect signaling – DE-STA-CO F5-B AC Inverter Drive User Manual
Page 30
30
Installation and Connection
Incorrect
Signaling
ST
(pin 16)
Quick Stop
(pin 10)
Start
(pin 14)
Stop
(pin 11)
Motor
(RPM)
ST: Must be high
Quick Stop: Must be high
Start pulse: Motor accelerates and runs at speed
Stop signal: Motor decelerates and stops at a repeatable
distance from the stop sensor (sensor still made)
* Incorrect singaling
1. Start pulse overrides the stop signal
2. Start input must be low for stop signal to function
Must drive off of stop sensor
with start signal
Incorrect
Signaling
ST
(pin 16)
Quick Stop
(pin 10)
Start
(pin 14)
Stop
(pin 11)
Motor
(RPM)
ST: Must be high
Quick Stop: Must be high
Start pulse: Motor accelerates and runs at speed
Stop signal: Motor decelerates and stops at a repeatable
distance from the stop sensor
* Incorrect singaling
1. Start pulse overrides the stop signal
2. Start input must be low for stop signal to function
6ms minimum pulse
Indexing Mode
Indexing Mode - Stopping on stop sensor
Examples of Correct and Incorrect Signaling