36

"Forward Acceleration" drive accelerates with direction of
rotation forward .

"Forward Deceleration" drive decelerates with direction of
rotation forward.

"Reverse Acceleration" drive accelerates with direction of
rotation reverse.

"Reverse Deceleration" drive decelerates with direction of
rotation reverse.

"Forward Constant" drive runs with a constant speed and
direction of rotation forward.

"Reverse Constant" drive runs with constant speed and direc-
tion of rotation reverse.

Other status messages; such as error(E.xxx) and malfunction
(A.xx) codes, are described towards the end of this manual.

Operation of the Drive

CP.4 makes it possible to display the peak inverter loading during
operation in percent. Only positive values are displayed, meaning there
is no differentiation between motor and regenerative operation.

Actual inverter

load

Display of the actual inverter loading in percent. 100% rate of utilization is
equal to the inverter rated current. Only positive values are displayed,
meaning there is no difference between motor and regenerative opera-
tion.

Peak inverter load

The inverter will output the applied input voltage or the voltage value
adjusted in CP.17 at the frequency value adjusted in this parameter. This
parameter is typically adjusted for the motor rated frequency. Note:
Motors can overheat when the rated frequency is incorrectly ad-
justed!

Adjustment range:

0...400 Hz

Resolution:

0.0125 Hz

Factory setting:

60 Hz

Rated frequency

4.5 Adjustment of the

Drive

The following parameters determine the fundamental
operating data of the drive. They should be checked and/or
adjusted for the application.