Intermodulation

0 dB RF attenuation, preselection/preamplifier = OFF

1

≤3.6 GHz

+13 dBm, nominal

>3.6 GHz

R&S

®

ESU8

+10 dBm, nominal

1 dB compression of input mixer

R&S

®

ESU26/40

+7 dBm, nominal

level 2 × –10 dBm, Δf > 5 × RBW or 10 kHz, whichever is larger
preselection/preamplifier = OFF

1

R&S

®

ESU8

10 MHz ≤ f

in

< 300 MHz

>17 dBm, typ. 20 dBm

300 MHz ≤ f

in

< 3.6 GHz

>20 dBm, typ. 25 dBm

3.6 GHz ≤ f

in

≤ 8 GHz

>18 dBm, typ. 23 dBm

R&S

®

ESU26, R&S

®

ESU40

10 MHz ≤ f

in

< 300 MHz

>17 dBm, typ. 20 dBm

300 MHz ≤ f

in

< 3.6 GHz

>22 dBm, typ. 27 dBm

3.6 GHz ≤ f

in

≤ 26.5 GHz

>12 dBm, typ. 15 dBm

R&S

®

ESU40

26.5 GHz < f

in

≤ 40 GHz

>12 dBm, typ. 15 dBm

preselection = ON, preamplifier = OFF

10 MHz ≤ f

in

< 300 MHz

>9 dBm, typ. 12 dBm

300 MHz ≤ f

in

≤ 3.6 GHz

>12 dBm, typ. 15 dBm

preselection = ON, preamplifier = ON

Third-order intercept point (TOI)

10 MHz ≤ f

in

≤ 3.6 GHz

>–10 dBm, typ. –7 dBm

preselection/preamplifier = OFF

1

f < 100 MHz

>35 dBm

100 MHz < f

in

≤ 400 MHz

>45 dBm, typ. 55 dBm

400 MHz < f

in

≤ 500 MHz

>52 dBm, typ. 60 dBm

500 MHz < f

in

≤ 1 GHz

>45 dBm, typ. 55 dBm

1 GHz < f

in

≤ 1.8 GHz

>35 dBm

f

in

> 1.8 GHz

>80 dBm, nominal

preselection = ON, preamplifier = OFF

f

in

< 100 MHz

>40 dBm

100 MHz < f

in

≤ 1.8 GHz

>55 dBm, typ. 65 dBm

preselection = ON, preamplifier = ON

f

in

< 100 MHz

>35 dBm

Second harmonic intercept (SHI)

100 MHz < f

in

≤ 1.8 GHz

>45 dBm, typ. 55 dBm

Displayed average noise level (analyzer mode)

RF attenuation = 0 dB, termination = 50 Ω, log. scaling, normalized to 1 Hz RBW,
preselection = OFF, preamplifier = OFF
f < 10 kHz: 10 Hz FFT Filter, trace average, sweep count = 20
f ≥ 10 kHz: RBW = 1 kHz, VBW = 3 kHz, span = 0 Hz, sweep time = 50 ms, trace
average, sample detector, sweep count = 20, mean marker
all models

20 Hz

<–90 dBm

100 Hz

<–110 dBm

1 kHz

<–120 dBm

10 kHz

<–130 dBm

100 kHz

<–130 dBm

1 MHz

<–140 dBm

10 MHz

<–153 dBm

R&S

®

ESU8

20 MHz ≤ f < 1 GHz

<–154 dBm, typ. –158 dBm

1 GHz ≤ f < 2 GHz

<–152 dBm, typ. –155 dBm

2 GHz ≤ f < 3.6 GHz

<–148 dBm, typ. –151 dBm

3.6 GHz ≤ f < 7 GHz

<–152 dBm, typ. –154 dBm

7 GHz ≤ f ≤ 8 GHz

<–150 dBm, typ. –152 dBm

1

Only available in analyzer mode.