beautypg.com

Atec Rohde-Schwarz-ESU-40 User Manual

Page 19

background image

Version 02.00, October 2007

R&S

®

ESU EMI Test Receiver

19

RF attenuation = 0 dB, termination = 50 Ω, log. scaling, normalized to 1 Hz RBW
preselection = ON, preamplifier = ON

4

f < 10 kHz: RBW = 10 Hz, VBW = 30 Hz, trace average, sample detector,
sweep count = 20, mean marker
f ≥ 10 kHz: RBW = 1 kHz, VBW = 3 kHz, span = 0 Hz, sweep time = 50 ms, trace
average, sample detector, sweep count = 20, mean marker
all models

1 kHz

<–130 dBm

10 kHz

<–140 dBm

100 kHz

<–140 dBm

1 MHz

<–150 dBm

10 MHz

<–165 dBm

R&S

®

ESU8:

20 MHz ≤ f < 500 MHz

<–165 dBm, typ. –168 dBm

500 MHz ≤ f < 2 GHz

<–162 dBm, typ. –165 dBm

2 GHz ≤ f < 3 GHz

<–159 dBm, typ. –162 dBm

3 GHz ≤ f < 3.6 GHz

<–154 dBm, typ. –157 dBm

3.6 GHz ≤ f < 6 GHz

<–162 dBm, typ. –165 dBm

6 GHz ≤ f ≤ 8 GHz

<–160 dBm, typ. –163 dBm

R&S

®

ESU26:

20 MHz ≤ f < 2 GHz

<–162 dBm, typ. –165 dBm

2 GHz ≤ f < 3 GHz

<–158 dBm, typ. –161 dBm

3 GHz ≤ f < 3.6 GHz

<–155 dBm, typ. –158 dBm

3.6 GHz ≤ f < 13 GHz

<–165 dBm, typ. –168 dBm

13 GHz ≤ f < 22 GHz

<–163 dBm, typ. –165 dBm

22 GHz ≤ f ≤ 26.5 GHz

<–160 dBm, typ. –163 dBm

R&S

®

ESU40:

20 MHz ≤ f < 2 GHz

<–162 dBm, typ. –165 dBm

2 GHz ≤ f < 3 GHz

<–158 dBm, typ. –161 dBm

3 GHz ≤ f < 3.6 GHz

<–155 dBm, typ. –158 dBm

3.6 GHz ≤ f < 13 GHz

<–165 dBm, typ. –168 dBm

13 GHz ≤ f < 22 GHz

<–163 dBm, typ. –165 dBm

22 GHz ≤ f < 32 GHz

<–160 dBm, typ. –163 dBm

32 GHz ≤ f ≤ 40 GHz

<–155 dBm, typ. –158 dBm

0 dB RF attenuation, termination 50 Ω, log. scaling, normalized to 1 Hz RBW,
preselection = OFF, preamplifier = OFF, low-noise preamplifier = ON
RBW = 1 kHz, VBW = 3 kHz, zero span, sweep time 50 ms, trace average, sweep
count = 20, mean marker
all models

100 kHz

<–140 dBm

1 MHz

<–150 dBm

10 MHz

<-163 dBm

R&S

®

ESU8

20 MHz ≤ f < 2 GHz

<–165 dBm, typ. –168 dBm

2 GHz ≤ f < 3.6 GHz

<–163 dBm, typ. –166 dBm

3.6 GHz ≤ f < 6 GHz

<–162 dBm, typ. –165 dBm

6 GHz ≤ f ≤ 8 GHz

<–160 dBm, typ. –163 dBm

R&S

®

ESU26:

20 MHz ≤ f < 2 GHz

<–164 dBm, typ. –167 dBm

2 GHz ≤ f < 3 < 3.6 GHz

<–163 dBm, typ. –166 dBm

3.6 GHz ≤ f < 13 GHz

<–165 dBm, typ. –168 dBm

13 GHz ≤ f < 22 GHz

<–163 dBm, typ. –166 dBm

22 GHz ≤ f ≤ 26.5 GHz

<–160 dBm, typ. –163 dBm

R&S

®

ESU40:

20 MHz ≤ f < 2 GHz

<–164 dBm, typ. –167 dBm

2 GHz ≤ f < 3 < 3.6 GHz

<–163 dBm, typ. –166 dBm

3.6 GHz ≤ f < 13 GHz

<–165 dBm, typ. –168 dBm

13 GHz ≤ f < 22 GHz

<–163 dBm, typ. –166 dBm

22 GHz ≤ f < 32 GHz

<–160 dBm, typ. –163 dBm

32 GHz ≤ f ≤ 40 GHz

<–155 dBm, typ. –158 dBm

4

With option R&S

®

ESU-B24 the frequency range of the preamplifier is extended to the upper frequency limit of the instrument.