Atec Rohde-Schwarz-ESU-40 User Manual
Page 16
16 R&S
®
ESU EMI Test Receiver
Version 02.00, October 2007
Modulation
Modulation format
external
I/Q, AM, FM
full scale
AM, FM, V pp
1 V
Input voltage
I/Q
=
+
2
2
q
i
U
U
0.5 V
AM
f
center
> f
mod
, span = 0 Hz
Modulation depth
0 % to 99 %
0 Hz to 5 MHz
1 dB
Modulation frequency response
0 Hz to 30 MHz
3 dB
FM
f
center
> f
mod
, span = 0 Hz
Frequency deviation
full range: 100 Hz, 1 kHz, 10 kHz,
100 kHz, 1 MHz
deviation ≤10 MHz
0 Hz to 1 kHz
Modulation frequency range
deviation ≤1 MHz
0 Hz to 100 kHz
Modulation frequency response
0 kHz to 100 kHz
1 dB
I/Q modulation
f
center
> f
mod
, span = 0 Hz
0 Hz to 5 MHz
1 dB
Modulation frequency response
0 Hz to 30 MHz
3 dB
Modulation deviation of tracking
generator
I/Q modulation, typical values, baseband signals generated by the R&S
®
AMIQ
NADC/TETRA/PDC
RMS 2
%
peak 4
%
PHS
RMS 2
%
EVM
peak 5
%
GSM/DCS1800/PCS1900
RMS 1.5°
Phase error
peak 5°
Rho factor
IS-95 CDMA
0.997
Inputs and outputs (front panel)
RF output
N female, 50
Ω
100 kHz
≤ f < 2 GHz
1.2
VSWR
2 GHz
≤ f ≤ 3.6 GHz
1.5
Inputs and outputs (rear panel)
TG I/AM IN
BNC female
Impedance
50
Ω
Input voltage
V
pp
1
V
TG Q/FM IN
BNC female
Impedance
50
Ω
Input voltage
V
pp
1
V