beautypg.com

Atec Agilent-E8267D User Manual

Page 22

background image

22

Basic modulation types (custom format

)

PSK

BPSK, QPSK, OQPSK, π/4 DQPSK, 8PSK,

16PSK,

D8PSK

MSK

User-defined phase offset from 0 to 100 °

QAM

4, 16, 32, 64, 128, 256

FSK

Selectable: 2, 4, 8, 16 level symmetric, C4FM

User defined: Up to 16 custom deviation levels

Deviation resolution: 0.1 Hz

Symbol rate

Maximum deviation

< 5 MHz

4 times symbol rate

5 MHz to 50 MHz 20 MHz

User-defined I/Q

Custom map of 256 unique values

Vector accuracy

1

Formats: BPSK, QPSK, 16-256 QAM (α = 0.3, root

Nyquist filter, symbol rate 4 Msym/s)

EVM (% RMS)
≤ 20 GHz

< 1.2%, < 0.8% (typ)

> 20 to 32 GHz

< 1.3%

< 0.9% (typ)

> 32 to 44 GHz

< 1.4%

< 0.9% (typ)

Origin offset
250 kHz to 3.2 GHz

–45 dBc (typ)

3.2 to 44 GHz

–50 dBc (typ)

EVM (measured)

FIR filter
Selectable

Nyquist, root Nyquist, Gaussian, rectangular

α: 0 to 1, B

b

T: 0.1 to 1

Custom FIR

16-bit resolution, up to 64 symbols long,

automatically resampled to 1024 coefficients (maximum)

> 32 to 64 symbol filter: symbol rate ≤ 12.5 MHz

> 16 to 32 symbol filter: symbol rate ≤ 25 MHz

Internal filters switch to 16 tap when symbol rate

is between 25 and 50 MHz

Symbol rate
For external serial data:

Adjustable from 1000 symbols/sec to a maximum

symbol rate of 50 Mbits/sec ÷ (#bits/symbol)

For internally generated data:

Adjustable from 1000 symbols/sec to

50 Msymbols/second and a maximum of 8 bits per

symbol. Modulation quality may be degraded at

high symbol rates.

Internal baseband generator:
real-time mode

(Option 602)

1. Measured with Agilent 89441A vector signal analyzer. Valid after executing I/Q calibration, and instrument is maintained
within ±5 °C of calibration temperature. RF power < 0 dBm (Option 520) or < –3 dBm (Option 532, 544). When external inputs
are used, vector accuracy is equivalent to internal performance, after system calibration.

QPSK (measured)

Symbol Rate (Msymbol/sec)

EVM (%)

7

6

5

4

3

2

1

0

0 10 20 30 40 50

3 GHz

6 GHz

12 GHz

28 GHz

38 GHz

44 GHz

3 GHz

16 QAM (measured)

Symbol Rate (Msymbol/sec)

0 10 20 30 40 50

EVM (%)

4.5

4

3.5

3

2.5

2

1.5

1

0.5

0

3 GHz
6 GHz
12 GHz
28 GHz
38 GHz
44 GHz

3 GHz