Internal pulse generator (option unu or unw), Simultaneous modulation – Atec Agilent-E8267D User Manual
Page 16
![background image](/manuals/318647/16/background.png)
16
10 MHz to 3.2 GHz
Above 3.2 GHz
Width compression
(RF width relative to video out)
±5 ns (typ)
±5 ns (typ)
Video feed-through
1
< 125 mV pk-pk (typ)
< 2 mV pk-pk (typ)
Video delay (Ext input to video)
50 ns (nom)
50 ns (nom)
RF delay (video to RF output)
45 ns (nom)
35 ns (nom)
Pulse overshoot
< 15% (typ)
< 10% (typ)
Input level +1
V
peak
= RF On
+1 V
peak
= RF On
Input impedance
50 Ω (nom)
50 Ω (nom)
Modes
Free-run, triggered, triggered with delay, doublet,
and gated. Triggered with delay, doublet, and
gated modes require an external trigger source.
Period (PRI) (Tp)
70 ns to 42 s
(Repetition frequency: 0.024 Hz to 14.28 MHz)
Pulse width (Tw)
10 ns to 42 s
Delay (Td)
Free-run mode
0 to ±42 s
Triggered with delay and doublet modes 75 ns to 42 s with ±10 ns jitter
Resolution
10 ns (width, delay, and PRI)
All modulation types (FM, AM, ΦM, pulse. and I/Q) may be simultaneously enabled except:
FM with ΦM, linear AM with exponential AM, and wideband AM with I/Q. AM, FM, and
ΦM can sum simultaneous inputs from any two sources (Ext1, Ext2, internal1, or internal2).
Any given source (Ext1, Ext2, internal1, or internal2) may be routed to only one activated
modulation type.
Internal pulse generator
(Option UNU or UNW)
Measured pulse modulation envelope
Freq = 10 GHz, Amp = 10 dBM, ALC = Off, Pulse width = 50 ns
Timebase (nsec)
0 10 20 30 40 50 60 70 80 90 100
Sync
output
Video
output
RF pulse
output
Td
Tm
Tw
Trf
Vf
Tf
Tr
Vor
Tp
50%
50%
10%
90%
50%
1. With attenuator in 0 dB position. Video feed-through decreases with attenuator setting.
Td video delay (variable)
Tw video pulse width (variable)
Tp pulse period (variable)
Tm RF delay
Trf RF pulse width
Tf RF pulse fall time
Tr RF pulse rise time
Vor pulse overshoot
Vf video feedthrough
Simultaneous modulation