beautypg.com

10 measurement time – Atec Anritsu-ME7838A User Manual

Page 8

background image

8

PN: 11410-00593 Rev. D

ME7838A BB/mm-Wave VNA TDS

Broadband Specifications and Performance

VectorStar ME7838A BB/mm-Wave VNA

2.10 Measurement Time

Measurement times include sweep time, retrace time, and band-switching time. Typical.

Measurement Time (ms)

Full Band, 70 kHz to 110 GHz, Display ON, and ALC ON.

Calibration

IFBW

Measurement Time (ms)

a

a. Measurement times are for ME7838A Broadband and ME7838A Millimeter-Wave Systems.

1-port calibration

1 MHz

80

100

350

700

30 kHz

90

160

600

1500

10 kHz

110

240

1100

2600

1 kHz

470

1600

10,000

25,000

10 Hz

47,000

160,000

1,000,000

2,500,000

2-port calibration

1 MHz

160

200

700

1400

30 kHz

180

320

1200

3000

10 kHz

220

480

2200

5200

1 kHz

940

3200

20,000

50,000

10 Hz

94,000

320,000

2,000,000

5,000,000

Measurement Time (ms) vs. System Dynamic Range (dB)

Full Band, Display ON, and ALC ON.

Calibration

401 Points

Measurement Time

Achieved System Dynamic

Range (Opt 062 at 54 GHz)

IFBW and Averaging Used

Uncorrected or

1-port calibration

110

470

77

87

10 kHz/no avg

1 kHz/no avg

2-port calibration

220

940

77

87

10 kHz/no avg

1 kHz/no avg

401 Points

1,601 Points

10,001 Points

25,000 Points