Full frequency band sweep time (ms)

1

Number of Points

Measurement

51

201

401

1601

(Stepped mode/Swept mode)

Single Band Sweep (10 to 12 GHz)
Uncorrected

170/56

523/93

999/143

3866/443

One-port calibration

2

170/56

523/93

999/143

3866/443

Two-port calibration

3

331/100

1053/173

2024/272

7880/872

Agilent 8719D Full Sweep (0.05 to 13.5 GHz)
Uncorrected

612/496

1055/589

1539/651

4371/951

One-port calibration

2

612/496

1055/589

1539/651

4371/951

Two-port calibration

3

1217/977

2118/1166 3100/1287 8911/1892

Agilent 8720D Full Sweep (0.05 to 20 GHz)
Uncorrected

585/447

1068/580

1548/637

4386/939

One-port calibration

2

585/447

1068/580

1548/637

4386/939

Two-port calibration

3

1162/880

2144/1147 3123/1263 8942/1865

Agilent 8722D Full Sweep (0.05 to 40 GHz)
Uncorrected

760/581

1281/696

1733/713

4649/995

One-port calibration

2

760/581

1281/696

1733/713

4649/995

Two-port calibration

3

1510/1144 2572/1376 3497/1414 9478/1976

Time Domain Conversion

4

13

44

90

387

GPIB Data Transfer

5

13

18

25

61

Binary (Internal)

IEEE754 floating point format
32 bit

14

21

31

89

64 bit

16

30

48

153

ASCII

52

181

355

1391

1. All values are typical.
2. S11 one-port calibration, with a 6 kHz IF bandwidth. Includes system retrace time.

Time domain gating is assumed off.

3. S21 measurement with full two-port calibration, using a 6 kHz IF bandwidth.

Includes system retrace time and RF switching time. Time domain gating is
assumed off.

4. Option 010 only, gating and error-correction are off. Does not include sweep time.
5. Measured with an HP Omnibook 5500 133 Pentium computer.

Measurement throughput summary