2.3 Network Connectivity Overview

The XP-DSM cable modem must be recognized by the CMTS as a valid device to be

assigned an IP address from the DHCP server, locate the TFTP and TOD servers, and

communicate with the SNMP management server (trap receiver) (see

Section 2.5

).

CMTS and system vendors use different security methods to insure network integrity, but

common considerations are:

• MAC filtering may have to be modified to allow RF MAC registration of addresses starting

with 00.05:CA and 00:03:08.

• For SNMP access, UDP ports 161 & 162 must not be blocked.

• For TFTP access, port 69 must not be blocked.

• For HTTP access, port 80 must not be blocked.

• For Web access with firmware version 1.05.0, allow traffic on port 61520.

• Firewalls must allow communication between the cable modem and the TFTP, DHCP,

SNMP, and TOD servers.

• If the address of the TFTP or TOD server is different than the DHCP server, the response

from the DHCP server must contain the TFTP and TOD addresses.

2.0

System Overview, continued

2.4 System Configuration and Installation Overview

NOTE:

Before installation read all of the “System Overview” Sections.

XP-DSM installation and setup is comprised of three basic steps:

1. Configuring the Network: provisioning the DHCP Server with the transponder’s MAC

Address (Section 3.1) and assigning it a DOCSIS Configuration File (

Section 3.2

).

2. Setting Options: There are a number of ways transponder options can be set.

They can be set automatically before or after hardware installation via the DOCSIS

Configuration File or the DSM Setup File (see

Sections 3.2

and

3.4

), remotely after

installation of the hardware (

Section 3.3

), or locally by plugging a computer directly

into the transponder’s local port (

Section 4.0

). The SCTE-HMS and Alpha MIBs

need to be compiled into a MIB browser before it can be used to monitor or set

transponder and power supply parameters (

Section 6.0

).

3. Field Installation: a straight-forward procedure that consists of installing the XP-

DSM into the power supply (

Section 7.0

), installing the battery sense wire harnesses

(

Section 8.0

), and verifying operation (

Section 9.0

).

These steps can be performed independently of one another. However, configuring the

network prior to field installation will allow the installation to be verified while personnel are

still on-site (

Section 9.0

). Performing field installation before network configuration—before

the installation can be verified—might result in additional field service calls to correct

mistakes.
Carefully read the following section in order to understand the dependencies within the

system before performing system configuration or hardware installation.