Installation Instructions for Specifi c Power Supplies, continued

3.2

Alpha XM Series Power Supply, continued

3.2.4 Provisioning the Network for the XM Series

The transponder must be recognized by the CMTS as a valid device, obtain an IP
address, and communicate with the SNMP management server.

Load the transponder’s MAC address into the CMTS.

1.

Setup SNMP using two proprietary MIBs fi les.

2.

Compile the two MIBs onto a network manager or MIB browser software.

3.

Set the MIBS points for the XM as follows:

4.

Oid: 1.3.6.1.4.1.2183.2.3.3.1.2 set to (3) (power supply

selection)

Oid: 1.3.6.1.4.1.2183.2.3.6.5 set to (4) (output voltage

scaling)

Oid: 1.3.6.1.4.1.2183.2.3.6.6 set to (1)for 110V powered

supply or (2) for 220V (input voltage measurement)

Install and confi gure the DOCSIS confi guration fi le. See Section 2.1.9 for a

5.

sample fi le.

See Section 4.0, Proprietary Management Information Bases (MIBs) for detailed
information.