beautypg.com

Installation – Alpha Technologies FlexPoint AX Series User Manual

Page 21

background image

21

010-318-C0-007, Rev. G

1. Mount the Home Converter horizontally in a convenient interior

location near an AC outlet, using two (2) 8-32 pan head screws
(for placement over studs) or Molly bolts (for mounting on
drywall) long enough to support a 1-lb. unit.

2. Strip 1/4" from the cable wire ends. Connect the cable from the

Power-Ring into the 3-pin plug in the following order:

Pin 1, white (return), Pin 2, black (12V) Pin 3, green (control).

Tighten the plug screws with a 0.100" jeweler’s screwdriver. To
reduce the potential for a short circuit, verify no bare wire
is showing, or loose strands of wire are present between
the cables.

3. Verify orientation of plug and snap the 3-pin plug into the Home

Converter. Do not force the plug into the converter.

4. Secure the cable to the base of the converter by threading a

cable tie through the two holes on the extension at the base of
the Converter. Tighten the cable tie and trim the excess.

4.2

Installing the Power-Ring Converter, continued

5. Use

fl at-bladed screwdriver to remove blanking plate from Power-Ring.

6. Insert AX-30 module into meter base. The module will lock into place when fully inserted.

Blanking Plate

AX-30

Pin 1

.

To ONT

Minimize Gap

Strain

Relief

Insert
screwdriver here,
twist to remove
plate

If the Power-Ring Converter is part of an Outdoor Non-UPS confi guration, proceed to Section 6.1, “Activating
the Power-Ring Converter”. Otherwise, continue to Section 5.0, “ Installing the Battery Module”

NOTE:

Refer to the NOTE in Section 2.0, “Applications” for wire size and distance.

NOTE:

If the Home Converter is part of an Indoor to Outdoor Non-UPS confi guration, proceed to Section 5.2,
“Activating the Home Converter".

NOTE:

4. Installation

4.3

Installing the Home Converter