beautypg.com

Applications, 3 outdoor ups confi guration, 4 indoor to outdoor ups confi guration – Alpha Technologies FlexPoint AX Series User Manual

Page 13

background image

13

010-318-C0-007, Rev. G

2. Applications

NID/NIU/ONT

Cable through wall

AX18-12-HC

Indoor 120Vac

outlet

Indoors to Outdoors

Cable length under 100’

• UPS

required

Less than 10' of cable

(+/- and Alarms)

(See NOTE 2)

NOTE:

1. Use 14AWG (preferred) to 16AWG (minimum) for the cabling between the Home Converter/Power

Converter and battery housing. Use only cable rated for the outdoor environment. The maximum cable
length is determined by the maximum output voltage of the Power Converter/Home Converter minus the
voltage drop required by the Battery Module to properly charge the battery.

2. Use 18AWG (minimum) stranded cable for the +/- connections, and 18AWG to 22AWG cable for the

alarm connections between the battery housing and the NID/NIU/ONT. Use only cable rated for the
outdoor environment. The maximum cable length is calculated such that the minimum input voltage of the
ONT used in the confi guration is less than or equal to the lowest battery voltage (just above battery cutoff)
minus the voltage drop of the cable.

AX-12D-BBPS

Battery Housing

(shown)

Distance

Wire Size

0'–50'

#16 AWG

50'–100'

#14 AWG

11.6Vdc to 16Vdc

nominal output voltage

11.6-16 Vdc output

voltage

8' in length

Less than 10' of cable

(+/- and Alarms)

(See NOTE 3)

2.3

Outdoor UPS Confi guration

• Outdoors

Cable length under 100'

• UPS

required

2.4

Indoor to Outdoor UPS Confi guration

NID/NIU/ONT

AX-POWER-RING
and AX18-12D-PC

Assembly installed in

meter base

AX-12D-BBPS

Battery Housing

(shown)

Up to 100' of three wire (+, -, and control) cable

(See NOTE 2)

Up to 100' of three wire

(+, -, and control)

cable (See NOTE 1)