Connection examples for an electronic door opener/door bell


Description of the terminal block







Description

Note

12V-24

AC/DC

Network connection for video door station 12-24V direct current or

12-24V alternating current

RELAY

1

Terminal connector for electronic door opener.

Potential-free relay, NO (normally open)

RELAY

2

Terminal connector for electronic door bell.

Potential-free relay, NO (normally open)

Connection for an electronic door opener:

Connect the electronic door opener to RELAY 1, using either a separate power supply unit (version A) or
directly (version B) via the power supply of the video door station.

For version B, take note of the permitted power supply for your door opener:

A voltage that is too high can damage your door opener.

If the power consumption is too high for the switching procedure, the network supply
for your video door station can fail. Ensure that the power supply unit for your video
door station has a sufficient rating (min. 1A or higher).

230V

230V

230V

Version A

Version B