beautypg.com

Franklin Fueling Systems DC404-4 Controller User Manual

Page 9

background image

9

Figure 11: 404-4 Wired to a Tokheim 262 or 262A Dispenser

Dispenser

Breaker

ORG/BLK

ORG

BLK

WHT

Sensor

404-4 Controller

12A, 240VAC

G

G

GRN/YEL

GRN

120-240VAC

Main Junction Box

BLK - ACH

BLK - ACH

WHT - ACC

WHT - ACC

Figure 12: 404-4 Wired to a Tokheim Premier Dispenser

Dispenser

Breaker

ORG/BLK

ORG

BLK

WHT

Sensor

404-4 Controller

12A, 240VAC

G

G

GRN/YEL

GRN

120-240VAC

Dispenser Junction Box

UDC - ACH

9

UDC - ACC

10