Wall Mounting the TLP 700MV

The TLP 700MV can be mounted in the wall or through furniture. Extron recommends
using the Extron TR 700M trim ring to conceal any ragged edges when the hole is cut in
the wall or furniture.
To mount the TLP 700MV directly into a wall, follow these steps. The steps are similar if
the unit is mounted in furniture (such as a podium or table).

1.

Determine the best location for the TLP 700MV.

2.

Use the template provided to mark the wall or furniture and cut a hole.

3.

Unpack the TLP 700MV and remove the bezel.

4.

Ensure all the locking arms are flush with the unit and check that the TLP 700MV can
fit into the hole. If necessary, use a rasp or a coarse file to enlarge the hole.

5.

Place the TR 700M trim ring around the hole. Ensure the trim ring is horizontal (use
a level if necessary) and mark the four holes (one in each corner) where it will be
secured around the hole.

6.

Drill four holes and secure the trim ring to the wall, covering any ragged edges to the
hole.

7.

Run the network cable and video connectors inside the wall to the hole, leaving
enough slack in the cables to connect them to the back of the TLP 700MV.

8.

Plug the cables into the

rear panel connectors

(see page 7).

Connect the

LAN port

to the network with a straight-through cable.

Connect an

S-video or composite video

source to the unit, using the two BNC

connectors:

z

z

For S-video, connect the Y (luminance) signal to the VID/Y input and the C
(chrominance) signal to the C input.

z

z

For composite video, connect the input to the VID/Y input.

Connect the

power input

to the provided power supply using the 2-pole captive

screw connector. See the

Caution

on page 6 for very important information about

power supplies.

9.

Push excess cables into the wall cavity and fit the TLP 700MV into the hole.

10.

Use a Phillips head screwdriver to tighten the screws. As the screws tighten, the
locking arms rotate into position behind the wall and hold the unit in place. Do not
overtighten the screws as this can damage the catches or the wall.