Mounting, Tabletop placement, Rack mounting – Extron Electronics MLA VC10 Plus User Guide User Manual
Page 43: Ul guidelines for rack mounting, Tabletop placement rack mounting, Requirements

Mounting
This section outlines the various mounting options available for the MLA VC10 Plus:
z
z
z
z
Tabletop Placement
Attach the four provided rubber feet to the bottom of the unit and place it in any suitable
location.
Rack Mounting
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe installation
of this product in a rack:
1.
Elevated operating ambient temperature — If the unit is installed in a closed or
multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore, install the equipment in
an environment compatible with the maximum ambient temperature (TMA: +122 °F,
+50 °C) specified by Extron.
2.
Reduced air flow — Install the equipment in the rack so that the equipment gets
adequate air flow for safe operation.
3.
Mechanical loading — Mount the equipment in the rack so that uneven mechanical
loading does not create a hazardous condition.
4.
Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of the equipment nameplate ratings should be used when
addressing this concern.
5.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct
connections to the branch circuit (such as the use of power strips).
MLA VC10 Plus • Mounting
37