The MLA VC10 Plus does not respond to SIS commands
z
(
a
in
) — it flashes green when SIS
commands are received.
z
The MLA VC10 Plus may not be receiving RS-232 commands correctly. Check the
connections between the control device and the MLA VC10 Plus
. Ensure the Tx
and Rx wiring is not reversed (see pages 13 and 14).
z
Check the baud rate is 9600 bps, 8 data bits, 1 stop bit, no parity.
There is no audio output
z
Check that the master volume on the amplifier is not set to minimum.
z
Check the wiring to the amplifier or mixer to make sure the MLA VC10 Plus is
connected to the correct remote volume terminals (see page 6 if
or page 8 if using
).
z
Verify that all the equipment is powered on.
z
Ensure the front panel USB connection is removed and recycle power to the
f
in the
on page 4).
z
b
in
). It lights solid green when the volume is set to 0
or muted. Use SIS commands to
(see page 33).
z
Check that the correct control mode (voltage or potentiometer) is selected. If
necessary, use SIS commands to change to the
(see page 35).
z
If the relay is connected to mute control, check the
(
c
) to
see whether the relay is on. Use SIS commands to
(page 34) or
(page 33).
The MLA VC10 Plus does not provide a good volume sweep range (cannot reach
maximum volume or there is no volume change in a certain range)
z
Ensure the amplifier gain is set correctly. If the amplifier has a master volume knob,
this must be set to the maximum desired level.
z
Ensure that the proper
, required by the amplifier, has been set.
z
Ensure the correct
, required by the amplifier, has been set.
z
When a maximum range limit is applied to the resistance control, it only limits the
maximum resistance across the wiper (C) and ground (G) pins. This usually limits the
maximum volume output from the amplifier. The resistance between the reference (V)
and ground (G) pins of the MLA VC10 Plus is always fixed at 10 kilohms.
Extron recommends that for three-terminal potentiometer control, the maximum
resistance output should remain at 10 kilohm, to provide the optimum volume range.
NOTE: Some amplifiers do not obtain good maximum or minimum volume
control through their remote volume terminals.
The output is noisy or has static
z
It may be necessary to move the amplifier or mixer and MLA VC10 Plus away from
sources of electromagnetic interference, such as appliances and large motors.
z
If the voltage control cable is too long, noise may be picked up from many sources.
Use a shielded cable that is no longer than 6 feet between the MLA VC10 Plus and
the amplifier. For best results, Extron recommends placing the MLA VC10 Plus as close
as possible to the amplifier.