beautypg.com

Volume, Control, Port – Extron Electronics IPCP Pro Series User Guide User Manual

Page 27: Preliminary, Figure 17. volume control port wiring examples

background image

IPCP Pro Series • Hardware Features and Installation

21

K

Volume control port — To provide volume control for Extron half rack audio amplifiers,

connect this port to the volume remote control port on the amplifier as shown below.
Configure the maximum and minimum voltage limits. Set Soft Start mode off or on
(default) . Soft Start mode allows volume to gradually increase from mute to the previous
level after muting or power-on to prevent loud audio bursts

10V 50mA

G

C

V

REMOTE

10V 50mA

G

C

V

10V

REMOTE

VOL/MUTE

REMOTE

VOL/MUTE

10V 50mA

G

ST

ANDBY

10V 50mA

G

C

V

V C G

V C G

VOL

V C G

VOL

Ground (Gnd)

C

G

V

Ground

Reference voltage

C

G

Control voltage

V

Reference voltage input (from amplifier) – This allows the IPCP Pro to detect when the amp is present.

Control voltage (variable output to amp from IPCP Pro) – This signal controls the amp volume.

Example:

Connecting to

Extron Amplifiers

IPCP Pro

Rear

Panel

C or VOL/MUTE

V or 10V

G or

MPA 401 Series

MPA 181T,

MP 101 Series

MPA 152

MPA 152 Plus

XPA 1002

Rear Panel

Control voltage output:

0 - 10 VDC

Reference

voltage: ≤10 VDC

Volume Control

This port can be used to control the volume and mute or

unmute the audio for Extron half rack width audio amplifiers.
• Connect to an Extron audio ampifier to permit volume

control via touchpanel controls, macros, or schedules.

• Do not exceed 10 VDC input voltage.

Configure the maximum and minimum voltage limits. Set

Soft Start mode off or on (default) . Soft Start mode allows

volume to gradually increase from mute to the previous level

after muting or power-on to prevent loud audio bursts

NOTE:

Use shielded cable and

place the control processor
as close as possible to the
amplifier to avoid picking up
background noise via the
cable. Ideal cable length is
six feet or less.

NOTE:

When audio mute is active, the

control processor sets output voltage
to 0 VDC, even if the voltage range
(minimum and maximum voltage
limits) has been set to levels above
zero, such as 2 V to 8 V.

Figure 17.

Volume Control Port Wiring Examples

PRELIMINARY