Power connections, Power input, Connector (internal – Extron Electronics IPCP Pro Series User Guide User Manual
Page 19: Power supply), Connector (external, Preliminary, Figure 8. connecting an internal power supply

IPCP Pro Series • Hardware Features and Installation
13
Power Connections
A
Power input connector (external power supply) — Connect the IPCP to the
included 12 VDC power supply here, then connect the external power supply to a 100
to 240 VAC power source.
POWER
12V
x.xA MAX
R
Ground
all devices.
External
Power Supply
(12 VDC, 1 A max.)
– Return
+12 VDC input
Ridged
Smooth
1A MA
X
100-240V 50-60Hz
Rear
Panel
Front Panel
NOTE:
Check the polarity of the power
supply before connecting it to the IPCP.
Ridged
Smooth
Tie Wrap
3/16"
(5 mm)
Max.
Power Input, External Power Supply
• Front panel LED ( ) blinks during
boot-up and lights when the IPCP
is powered and operational.
• Connect to
included 12 VDC
power supply.
Figure 7.
Connecting an External Power Supply
ATTENTION:
•
Always use a power supply supplied or specified by Extron. Use of an unauthorized
power supply voids all regulatory compliance certification and may cause damage to
the supply and the unit.
•
Utilisez toujours une source d’alimentation fournie par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute conformité
réglementaire et peut endommager la source d’alimentation ainsi que l’unité.
•
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities.
•
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une
utilisation dans les espaces d’aération ou dans les cavités murales.
•
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical
Code part 1, section 16. The power supply shall not be permanently fixed to building
structure or similar structure.
•
Cette installation doit toujours être en accord avec les mesures qui s’applique au
National Electrical Code ANSI/NFPA 70, article 725, et au Canadian Electrical Code,
partie 1, section 16. La source d’alimentation ne devra pas être fixée de façon
permanente à une structure de bâtiment ou à une structure similaire.
B
Power input connector (internal power supply) — Connect the IPCP to a
100 to 240 VAC power source here.
R
1.2A MAX
100-240V 50-60Hz
Power Input, Internal Power Supply
• Front panel LED ( ) blinks
during boot-up and lights
when the IPCP receives power.
• Connect to 100 to
240 VAC.
Rear Panel
Front Panel
Figure 8.
Connecting an Internal Power Supply