beautypg.com

Connections and wiring, Power connection, Local area network (lan) connection – Extron Electronics IPL T Series Setup Guide User Manual

Page 20: Power connection local area network (lan), Connection, 14 ipl t series • setup

background image

14

IPL T Series • Setup

Connections and Wiring

Power Connection

To connect the power supply:

1.

Insert the 2-pole captive screw connector into the power supply
receptacle on the rear panel of the controller.

SECTION A–A

Ridges

Smooth

Power Supply Output

Cord

A

A

3/16”

(5 mm) Max.

Power Supply Receptacle

DC Power Cord
Captive Screw Connector

AC Power Cord

Ground
+12 VDC

External

Power Supply

(12 VDC, 1 A )

COM1 COM2

LAN

POWER

12V

.5A MAX

FLEX I/O

2

1

3 4

1

IR

2

3

4

TX RX

TX RX

G

S

G

S

G

S

G

S

MAC: 00-05-A6-XX-XX-XX

S/N:

Figure 6.

Power Connector Wiring

2.

Connect the female end of the AC power cord into the power
supply and the male end into a 110-220 VAC outlet.

Local Area Network (LAN) Connection

Connect a patch (straight-through) Ethernet cable to the LAN port on
the rear panel if you are connecting the controller to a switch, hub, or
router on your A/V network.
Connect a crossover Ethernet cable to the LAN receptacle on the rear
panel if you are connecting the controller directly to a PC.

Local Area Network (LAN) Receptacle

COM1 COM2

LAN

POWER

12V

.5A MAX

FLEX I/O

2

1

3 4

1

IR

2

3

4

TX RX

TX RX

G

S

G

S

G

S

G

S

MAC: 00-05-A6-XX-XX-XX

S/N: