beautypg.com

3 function explanation – GE Industrial Solutions AF-300 G11 User Manual

Page 60

background image

5-7

Data subject to change without notice 7/07. © 2007 GE Drives

F00 Data protection

F 0 0

D A T A

P R T C

Set value

0 : data can be changed
1 : data cannot be changed

This function protects the system by blocking any data
changes from the keypad panel.

Setting procedure:

0 to 1:

Press the

STOP

and

keys simultaneously to

change the value from 0 to 1, then press

the

FUNC

DATA

to validate the change.

1 to 0:

Press the

STOP

and

keys simultaneously

to change the value from 1 to 0, then press

the

FUNC

DATA

key to validate the change.

F01 Frequency setting 1

F 0 1

F R E Q

C M D 1

This function determines the method to be used for setting
frequency.

NOTE: Use only one terminal - V2 or C1, exclusively.

0:

Keypad operation (

or

key)

1:

Voltage input (terminal 12 and V2) (0 to +10 VDC,
0 to +5VDC)

2:

Current input (terminal C1) (4 to 20 mA DC)

3:

Voltage and current input (terminals 12 and C1)

4:

Reversible operation with polarity (terminal 12)
(0 to

±

10 VDC)

Reversible operation with polarity (terminal 12 and V1
option) (0 to

±

10 VDC)

Related functions E01 to E09 (Set values 21

6:

Inverse mode operation (terminal 12 and V2)
(+10 to 0 VDC)

7:

Inverse mode operation ( terminal C1)(20 to 4 mA DC)

8:

UP/DOWN control 1 (initial freq. = 0 Hz

9:

UP/DOWN control 2 (initial freq. = last value)

Related functions E01 to E09 (Set values 17, 18)

10. PATTERN operation

Related functions: C21 to C28

11: DI option or Pulse train input
For details, see instruction manual on options.

F02 Operation method

F 0 2

O P R

M E T H O D

This function determines the input method for operation
commands.

0:

Keypad operation (

FWD

or

REV

or

STOP

key)

1:

Terminal operation (

STOP

key active)

2:

Terminal operation (

STOP

key inactive)

3:

Terminal operation (

STOP

key active) with GE start

software

4:

Terminal operation (

STOP

key inactive) with GE start

software

This function can only be changed when terminals

FWD

and

REV

are open.

REMOTE/LOCAL switching from the keypad panel
automatically changes the set value from 0 to 3 of this
function.

5.3 Function Explanation

F: Fundamental function