Absolute maximum ratings, Table 1. absolute maximum ratings, Table 2. input specifications – GE Industrial Solutions Zephyr Non-Isolated SMT User Manual
Page 2: Electrical specifications
![background image](/manuals/295732/2/background.png)
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only. Functional operation of the device is not implied at these or any other
conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute
maximum ratings for extended periods can adversely affect device reliability.
Table 1. Absolute Maximum Ratings
Parameter Device
Symbol
Min
Max
Unit
Input Voltage (continuous)
⎯
V
IN
– 0.5 13
V
O
UTEN
Terminal Voltage
⎯
V
OUTEN
– 0.5 6
V
Maximum Ambient
⎯
T
MAX
⎯
85 °C
Storage Temperature
⎯
V
STG
– 40 150
°C
External Voltage applied
between V
ADJUST
+ and V
ADJUST
-
⎯
V
EXT
0
3.5
V
Electrical Specifications
Table 2. Input Specifications
Parameter Device
Symbol
Min
Typical
Max
Unit
Operating Input Voltage
⎯
V
IN
4.5
12.6 V
Operating Input Current
• V
IN
= 12V, V
OUT
= 3.3V,
I
OUT
= 16A
• V
IN
= 5V, V
OUT
= 3.3V,
I
OUT
= 16A
∗
Depends on output voltage
⎯
⎯
I
IN
I
IN
⎯
⎯
⎯
⎯
5.5
∗
13.5
∗
A
A
LINEAGE
POWER
2