ProBee-ZE20S-HAxx User Guide Rev 1.9
83
OK
# Response
You can also send the identical command by using the AT+CCMD instead of the AT+LOCK command as
below:
AT+DEST=0000,01
# Set destination node address
OK
# Response
AT+CCMD=0101,10
# Send ‘Lock Response’ command
# Door Lock cluster(0x0101)
# Lock Response command(0x10)
OK
# Response
ProBeeHAxx firmware does not support all the commands in clusters. The AT+CCMD command can be
used instead of not all the commands but a few commands in clusters.
9.7
Receive HA Command
If your node receives HA Device Command, you can see following message.
+0000|HA_CLIENT_COMMAND|0101|00
# Received message
# 0x0101 (Door Lock cluster)
# 0x00 (Lock command)
* You can see Door Lock cluster command list in Chapter 6.4.2
9.8
Testing HA GPIO
HA GPIO can assign your GPIO pins to state attribute for monitoring. In ProBeeHAOL device, HA GPIO
pins are assigned to On/Off cluster, and in ProBeeHADL device, HA GPIO pins are assigned to Door Lock
cluster. You can see more information about HA GPIO in Chapter 4.2.
Example) Coordinator node is ProBeeHAOL and end device is ProBeeHACI.
# ProBeeHAOL node
AT+GPIO=66666666666666666
# Set all pins to HA GPIO
OK
# Response
Send HA commands to ProBeeHAOL coordinator from ProBeeHACI End Device for control HA GPIO as
below:
# ProBeeHACI node
AT+DEST=0000,01
# Set destination node to
OK
# Coordinator (ProBeeHAOL)
AT+OFF
# Send ‘Off’ command
OK
# Now HA GPIO pins changed to low