61

List of the existing networks

OK

7.5.2

AT+ESCAN or AT+ES

Description

Perform a scanning for energy level of all channels. It can be used to avoid

interference. It can take up to 5 seconds. The RSSI energy level ranges from

approximately -100 to +127 in dBm. (CAUTION: It is possible to cause a link error

if a node is a parent of an end-device.)

Execute

AT+ESCAN

AT+ESCAN=

Response

|

List of the RSSI for each channel

OK

7.5.3

AT+DSCAN or AT+DS

Description

Perform a scanning for existing nodes in the current network. A coordinator or

router can have children nodes and they are presented by “CLDn”. It can be

possible to place some conditions such as scan duration, node type and node

name in order. The information of local node is presented by “*”. (CAUTION: A

ProBee-Z*10 with PTv1.2 or earlier cannot receive the response of AT+DSCAN

from any ProBee-Z*10 with PTv1.3 or later. It cannot receive from any ProBee-

Z*20, either. In this case, it is recommended to upgrade PTv1.2 to the latest

version.)

Execute

AT+DSCAN or

AT+DSCAN= or

AT+DSCAN=, or

AT+DSCAN=,,

Response

|||||

name>

List of the existing nodes and information

OK

Range

Scan duration: 1 – 10

Node type: 0 – 4 (Zero indicates all node types.)

7.5.4

AT+RSSI or AT+RS

Description

Get RSSI and LQI information respectively for the delivery of the recent packet

across the last hot of the incoming route. The LQI value ranges from 0 to 255

with the maximum value representing the best possible link quality. The RSSI

value ranges from approximately -100 to +127 with each value representing the

energy level in dBm at the radio’s receiver. The sender of the recent packet and