SENA ProBee-ZE20S-HAOL User Manual
Page 64

ProBee-ZE20S-HAxx User Guide Rev 1.9
64
7.8.3
AT+NWKKEY or AT+NK
Description
Get/Set the 128-bit network key. (0 or 0s: generate random 128-bit number)
Execute
AT+NWKKEY?
AT+NWKKEY=
Response
OK
OK
Default
FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF
7.8.4
AT+UPDATEKEY or AT+UK
Description
Update the network key with a new generated key. (possible only for coordinator)
It is applied after 30s later because sending too quickly may cause a sleepy end-
device to miss the alternate encryption key and only get the switch key message,
which means it will be unable to change to the new network key.
Execute
AT+UPDATEKEY
Response
OK
7.9
UART
7.9.1
AT+BAUDRATE or AT+UB
Description
Get/Set the serial port speed for communication between the module serial port
and host.
Execute
AT+BAUDRATE?
AT+BAUDRATE=
Response
OK
OK
Default
9600
Range
300 – 230400
7.9.2
AT+DATABIT or AT+UD
Description
Get/Set the serial data bit setting on the module.
Execute
AT+DATABIT?
AT+DATABIT=
Response
OK
OK
Default
8
Range
7 – 8
7.9.3
AT+PARITY or AT+UP
Description
Get/Set the serial parity setting on the module.
Execute
AT+PARITY?
AT+PARITY=
Response
OK
OK