Response

List of the S-register

and description

OK

OK or ERROR

7.2.5

ATZ

Description

Reset the node.

Execute

ATZ

Response

OK

7.2.6

AT&F

Description

Factory reset.

Execute

AT&F

Response

OK

7.3

Node Specific Information

7.3.1

AT+LONGADDR or AT+LA

Description

Get the 64-bit IEEE address. (EUI address, long address) The IEEE address is a

unique device address assigned during manufacturing. This address is unique to

each physical device.

Execute

AT+LONGADDR?

Response

OK

7.3.2

AT+SHORTADDR or AT+SA

Description

Get the 16-bit Node ID. (network address, short address) The node ID of “0000”

is reserved for the coordinator. All other devices receive a randomly generated

address from the coordinator or router device that allows the join. This value can

change if an address conflict is detected where two devices are found to have the

same address or a device leaves the network and later joins.

Execute

AT+SHORTADDR?

Response

OK

7.3.3

AT+ADDRDISCOVERY or AT+AD

Description Get the corresponding address of a node whose long or short address is known.

Execute

AT+ADDRDISCOVERY= AT+ADDRDISCOVERY=

Response

OK

OK